摘要
Whatman41Paper electrophoresis employing Barbital buffer pH (9.0) at 300 volts for 3 hours separated the Vipera russelli (Indian Russell*s viper) venom in its basic components. This lead preliminary experiment helped in the selection of an appropriate HPLC (Shim Pack CLC-ODS (M)) column in a reverse operation/separation mode using 75% Acetonitrile as an eluent. Subsequent reverse phase preparative HPLC fractionated, the crude Russell*s viper venom into 10peaks, whose protein contents were quantitatively determined by the FCR method. Peak which showed the highest protein concentration was further subjected to SDS-PAGE electrophoresis, molecular weight determination and procoagulant activity profile.