摘要
Chemiluminescence immunoassay(CLⅠA) has always been a great challenge in detecting cardiac troponin Ⅰ(c Tn Ⅰ) in whole blood samples without centrifugation because of the interference of red blood cells and low sensitivity. Ⅰn this study, the antigens and erythrocytes in the blood were captured by the antibodies immobilized on the magnetic particles, recognized by another biotinconjugated c Tn Ⅰ antibody and detected by streptavidin/acridine aster-conjugated polychloromethylstyrene microspheres(PCMS). After magnetic separation, the supernatant was transferred and measured. No significant difference was noted between the c Tn Ⅰ concentrations of the serum samples,plasma samples and whole blood. The prepared PCMS provided more functional areas to conjugate streptavidin and acridinium ester, so the immunoassay has highly sensitive, the limits of blank at0.012 ng/m L, and functional sensitivity at 0.019 ng/m L with a CV of 20%, and 0.058 ng/m L with a CV of 10%. Total precision of any sample type ranged from 2.62%~5.67%. The assay was linear over the studied range of 0.01–50.00 ng/m L, and no hook effect was found when c Tn Ⅰ concentrations reached 1900 ng/m L. No significant interference was noted with the potential endogenous interfering substances. Compared with the commercial kit(Abbott assay kit), the correlation coefficient was 0.9859. A washing-free CLⅠA was established for the rapid detection of c Tn Ⅰ in human whole blood, using erythrocyte capture antibodies-conjugated magnetic nanoparticles for eliminating the influence of erythrocytes and PCMS for signal amplification, which showed great potential in clinical application.
-
单位东南大学; 生物电子学国家重点实验室